Skip to content
Nekker Labs
Engineering solutions · HVAC, Cooling & 3D/BIM
Specialty Hub 07 · Healthcare, Pharma & Cleanrooms

Hygienic AHUs, HEPA Filtration & Precision Climate for Clinics and GMP Pharma.

We engineer, verify at duty point and supply hygienic medical air handling units, multi-stage filtration up to H14, dehumidification/steam humidification, redundant MRI/process chillers and pressure-cascade automation paired with LOD 400 3D/BIM coordination for hospitals, operating suites, labs and GMP plants across Uzbekistan and Kazakhstan.

Cleanliness ClassesISO 5 - ISO 8 · GMP (Grades A / B / C / D)
Filtration StagesG4 + F7 + F9 + HEPA H13 / H14
Room ControlPressure Cascade ±10...30 Pa · t / RH%
BIM CoordinationLOD 400-500 · Clash-Free Clean Ceilings

Engineered Systems for Healthcare, Life Sciences & Clean Manufacturing

MED-01

Hygienic Air Handling Units (Medical & GMP Execution)

Smooth stainless-steel or antimicrobial interiors built for washdown disinfection and low leakage.

  • Crevice-free flush interior liners, L1/D1 low-leakage casings and sealed inspection doors
  • Sloped stainless-steel dry-drain condensate pans, UVGI germicidal sections and coated droplet eliminators
  • Redundant dual EC plug-fan arrays (2x100%) ensuring uninterrupted airflow for ORs and ICUs
MED-02

Terminal HEPA/ULPA Housings, Laminar Ceilings & Bubble-Tight Dampers

Maintaining sterility in surgical zones and containment in isolation/infectious wards.

  • Terminal H13 / H14 filter diffusers and unidirectional laminar airflow ceilings for operating theaters
  • Safe-change Bag-In / Bag-Out (BIBO) filter housings for infectious disease, BSL and nuclear medicine exhaust
  • Constant and variable volume (CAV / VAV) airflow regulators and gas-tight fumigation shutoff dampers
MED-03

Tight Temperature/Humidity Control (30-60% RH) & Redundant MRI Cooling

Year-round psychrometric precision and 24/7 process cooling for imaging and tablet production.

  • N+1 redundant RØNIQ Systems chillers with dual pump skids and glycol free cooling for MRI, CT and linear accelerators
  • Isothermal steam humidifiers and sub-dewpoint cooling coils with modulating reheat for GMP tablet/packaging suites
  • Close-control precision air conditioners for hospital server rooms and diagnostic equipment racks
MED-04

Room Pressure Cascade Automation & Interstitial Ceiling 3D/BIM

Coordinating ultra-dense above-ceiling MEP layers prior to modular cleanroom panel installation.

  • Airlock differential-pressure transmitters, flush room status monitors and GMP validation trend logging
  • Full LOD 400 Revit coordination of ductwork, medical gases, plumbing, surgical light booms and laminar plenums
  • As-Built LOD 500 + COBie digital twins tracking HEPA filter replacement intervals and VAV valve tags

Critical Engineering Checks for Medical & Cleanroom Projects

Engineering SubsystemCommon Unverified ErrorNekker Labs MethodValidation & Commissioning Result
Fan total static pressure across 3-4 filter stagesSizing fans for clean filters (400 Pa) instead of loaded G4+F7+F9+H14 final drop (900-1,200 Pa)EC fan arrays sized for dirty-filter final resistance with CAV constant-airflow controlStable air-change rates and room Pa cascade throughout filter life
Summer dehumidification without overcoolingSingle cooling coil without reheat drops OR temperature to +16 C while trying to lower RH%Sub-dewpoint cooling coil + modulating hydronic/electric reheat PID loopSimultaneous +20...+22 C and 45-55% RH stability
24/7 MRI & imaging chiller reliabilityComfort-grade chiller without redundancy or winter kit halts clinical imagingProcess N+1 chiller with buffer tank, glycol protection and -35 to +50 C ambient range365-day diagnostic uptime
Laminar ceiling clashes with beams & med-gasSupply ducts and terminal HEPA boxes fail to fit above cleanroom ceiling gridLOD 400 3D coordination including filter/VAV service access zonesZero ceiling tear-outs during cleanroom commissioning

Healthcare & Pharma Supply Across Uzbekistan & Kazakhstan

Supporting public and private hospitals, diagnostic centers and pharmaceutical plants:

Tashkent (Tashkent Pharma Park)AlmatyAstanaShymkentSamarkandBukharaKaragandaAktobeFergana

Medical & Cleanroom HVAC Questions

How does a hygienic medical AHU differ from a standard commercial AHU?

Hygienic units feature flush crevice-free stainless or antimicrobial internal surfaces, high-tightness casings, multi-slope stainless dry-drain pans, externalized wiring boxes and resistance to chemical washdown disinfectants.

Can your BIM team coordinate congested operating-room ceiling spaces in 3D?

Yes. Above-ceiling space in surgical and GMP suites is among the densest in construction. We build federated LOD 400 Revit models across HVAC, med-gas, cleanroom panels, structural and electrical systems before fabrication.

Technical sections & tools

Closer to manufacturer data.

Open the public Designer Workspace, browse engineering category guides or sign in to the project platform.

Let’s start with your project.

Email your HVAC equipment schedule, 3D/BIM pilot drawings or supply enquiry for engineering review.

Write an email
Projects and partnershipsinfo@nekkerlabs.com
Contacts
Rinat BaitemirProjects & Partnerships
+90 501 552 29 11
Alexandr KlimenkoKazakhstan · Almaty
+7 701 742 72 92
DIRECT PROJECT SUBMISSION

Attach drawings, equipment schedules, or BIM models

Upload PDF, DWG, RVT, IFC, Excel, or ZIP packages (up to 5 files, 100 MB total). Your submission creates an instant CRM dossier and alerts the regional desk.

Required scope
Project files or schedules (optional)
Drag and drop files here or click to browsePDF, XLSX, DWG, DXF, RVT, IFC, ZIP, PNG/JPG - up to 5 files, max 50 MB each / 100 MB batch
Offices & addresses
01 · Uzbekistan · Tashkent

OOO Nekker Labs

Uzbekistan, Tashkent, Yunusabad District, Bogishamol Street, 260A

Rinat Baitemirinfo@nekkerlabs.com
02 · Kazakhstan · Almaty

TOO Nekker

Kazakhstan, Almaty, Bostandyk District, Arkhat Microdistrict, Denis Ten Street, 2

Alexandr Klimenko+7 701 742 72 92
04 · USA · Wyoming

Nekker Labs

1309 Coffeen Avenue, STE 1200, Sheridan, Wyoming 82801