Category 04 · Controls, Hydronics & BMS Integration
Control panels, Kvs-sized valves & hydronic assemblies. Primary HVAC plant only performs as designed when valves, pumps, sensors and control logic are sized together. Nekker Labs supplies complete HVAC automation and hydronic packages matched to your AHUs, chillers and terminal units.
Panels Custom AHU / Plant Panels & VFDs
Valves 2/3-Way · Balancing · PICV
BMS Protocols Modbus RTU/TCP · BACnet
Hydronics Pumps · PHE · Mixing Skids
01 Category 04 · Controls, Hydronics & BMS Integration
Automation & hydronic scope of supply CTRL-01 HVAC & smoke control panels Pre-engineered power and PLC cabinets matched to exact AHU, pump and smoke fan configurations.
Hot-water and electric heater control with multi-layer freeze protection Variable frequency drives (VFDs) for constant-pressure or demand-controlled airflow and pumping Fire damper monitoring and smoke extraction / pressurisation control cabinets CTRL-02 Control, balancing & pressure-independent (PICV) valves Sized strictly by flow rate, differential pressure, Kvs and valve authority.
2-way and 3-way globe and characterizing ball valves with modulating 0-10 V actuators Manual and automatic riser balancing valves Pressure-independent control valves (PICV) simplifying commissioning on large towers CTRL-03 Coil mixing skids, heat exchangers & pump groups Prefabricated and modular hydronic assemblies for AHUs and plantrooms.
Complete AHU heating and cooling coil mixing assemblies Gasketed and brazed plate heat exchangers sized for low approach temperatures Inline and end-suction circulation pumps, headers, strainers and flexible joints CTRL-04 Field sensors, room thermostats & BMS gateways End-to-end instrumentation and open register maps for BMS integrators.
Duct, immersion and outdoor temperature, humidity, CO2 and differential pressure sensors Networked fan coil thermostats with deadband interlock Documented Modbus register tables and BACnet object lists 02 Project support
Why unified equipment + controls + hydronics prevents commissioning delays Interface Split-procurement failure Nekker Labs unified scope Commissioning outcome AHU <-> Mixing skid & panel Line-sized valve hunts and freezes heating coil Kvs sizing matched to coil flow and panel freeze-stat sequence Stable supply air temperature from day one Fan coils <-> Valve kits & stats 24 V actuators paired with 230 V thermostats or mismatched threads Verified voltage, thread and 2/4-pipe compatibility matrix Rapid floor-by-floor installation Chiller plant <-> BMS Missing flow switches, header sensors or protocol gateway cards All field sensors and BMS gateways included transparently in quote Smooth handover without variations
03 UZ · KZ
Controls & hydronics delivery across Uzbekistan & Kazakhstan Available as part of a turnkey HVAC package or standalone controls/hydronics scope:
Tashkent Almaty Astana Samarkand Shymkent Bukhara Atyrau Karaganda
Equipment categories & engineering services UZ HVAC supply, chillers & 3D/BIM in Uzbekistan KZ HVAC supply, ventilation & 3D/BIM in Kazakhstan UZ-01 Tashkent & Tashkent Region (OOO Nekker Labs) KZ-01 Almaty & Foothill Hub (TOO Nekker) KZ-02 Astana & Northern Kazakhstan (-40 C Winter) UZ-02 Samarkand, Bukhara, Navoi & Fergana KZ-03 Shymkent, Atyrau & Aktau (Ex & Marine) 01 Ventilation, AHUs & smoke control (AVZ) 02 High-ambient +50 °C chillers, fan coils & cooling (RØNIQ) 03 Multi-zone VRF/VRV, rooftops & heat pumps 05 Duty-point selection & HVAC schedule audit 06 Smoke Control 400/600 C, Pressurization & Jet Fans 07 Hygienic Medical AHUs, Cleanrooms & HEPA Filtration 08 LiDAR Scan-to-BIM & As-Built LOD 500 + COBie 09 AVZ - Industrial Fans, Smoke Exhaust & Fire Dampers 10 RØNIQ Systems - +50 C Chillers, Fan Coils & Rooftops 11 Industrial Plant Ventilation & Data Center Cooling G-01 Chiller-Fan Coil vs VRF for Hotels, Offices & Malls G-02 Specifying +46...+50 C High-Ambient Chillers G-03 High-Elevation (700-1,000 m) Fan & AHU Correction G-04 Arctic AHUs & Glycol Loops for -40 C Winters G-05 Smoke Control (400/600 C) & EI Damper Checklist G-06 When 3D/BIM (LOD 400) & Scan-to-BIM Pay Off BIM 3D / BIM (LOD 300 - 500) 04 FAQ
Questions on HVAC controls & hydronics Do you build control panels and mixing skids matched to selected AHUs? Yes. Every panel and mixing assembly is engineered around the exact fan currents, electric heater stages, damper actuators, heat recovery drive and coil flow of the selected AHU.
Do you provide wiring diagrams and Modbus register maps? Yes, full wiring schematics and Modbus / BACnet point schedules accompany the supplied controllers.
Technical sections & tools Closer to