Skip to content
Nekker Labs
Engineering solutions · HVAC, Cooling & 3D/BIM
Industrial & Commercial Cooling · RØNIQ Systems

RØNIQ Systems: +50 C high-ambient chillers, fan coils & rooftops.

We engineer and supply RØNIQ Systems cooling plants verified against factory selection sheets at real Central Asian summer peaks (+46...+50 C) as well as winter glycol free-cooling regimes in Northern Kazakhstan.

High AmbientFactory-verified at +46...+50 C ambient
Chiller PlantsAir-cooled, water-cooled, N+1 modular
Free-CoolingGlycol loops for Astana & Almaty
HydronicsPump skids, PICV valves & BMS panels

RØNIQ Systems lineup & complete hydronic scope

RNQ-01

Air-cooled High Ambient (T3 / +50 C) chillers

Screw, scroll, and inverter chillers with oversized condensers built for hot rooftops without HP trips.

  • True net cooling output verified at +46...+50 C (avoiding 18-25% hidden derating from +35 C tables)
  • Modular N+1 redundant plants for 4-5* hotels, hospitals, malls, and office towers
  • Low-noise EC condenser fan options for urban residential and hospitality sites
RNQ-02

Water-cooled chillers, free-cooling, rooftops & EC fan coils

End-to-end hydronic coordination from rooftop chiller plant to every terminal unit.

  • Integrated or remote glycol free-cooling with dry coolers for year-round cooling loads
  • 2-pipe and 4-pipe EC/AC fan coils, Kvs-sized PICV valves, buffer tanks, and Modbus/BACnet BMS

Pre-Supply Engineering Checks

ParameterCommon Procurement PitfallNekker Labs Verification
Cooling capacityOrdering off a +35 C brochure ratingFactory selection sheet at +46...+50 C & 7/12 C water
Glycol loopSizing pipes & pumps for pure water+7.8% flow & viscosity head recalculation (PG 40%)
Rooftop layoutPlacing units tight against parapet walls3D/BIM hot-air recirculation & acoustic clearance check

Regional supply & support

Project supply and commissioning support across Central Asia:

TashkentSamarkandBukharaNavoiShymkentAlmatyAstanaAtyrau

RØNIQ Systems chillers FAQ

How do you verify chiller performance for July peaks in Tashkent or Bukhara?

Every proposal includes the factory selection printout calculated specifically at the project design ambient (+46...+50 C) and actual chilled water temperatures (e.g., 12/7 C).

Technical sections & tools

Closer to manufacturer data.

Open the public Designer Workspace, browse engineering category guides or sign in to the project platform.

Let’s start with your project.

Email your HVAC equipment schedule, 3D/BIM pilot drawings or supply enquiry for engineering review.

Write an email
Projects and partnershipsinfo@nekkerlabs.com
Contacts
Rinat BaitemirProjects & Partnerships
+90 501 552 29 11
Alexandr KlimenkoKazakhstan · Almaty
+7 701 742 72 92
DIRECT PROJECT SUBMISSION

Attach drawings, equipment schedules, or BIM models

Upload PDF, DWG, RVT, IFC, Excel, or ZIP packages (up to 5 files, 100 MB total). Your submission creates an instant CRM dossier and alerts the regional desk.

Required scope
Project files or schedules (optional)
Drag and drop files here or click to browsePDF, XLSX, DWG, DXF, RVT, IFC, ZIP, PNG/JPG - up to 5 files, max 50 MB each / 100 MB batch
Offices & addresses
01 · Uzbekistan · Tashkent

OOO Nekker Labs

Uzbekistan, Tashkent, Yunusabad District, Bogishamol Street, 260A

Rinat Baitemirinfo@nekkerlabs.com
02 · Kazakhstan · Almaty

TOO Nekker

Kazakhstan, Almaty, Bostandyk District, Arkhat Microdistrict, Denis Ten Street, 2

Alexandr Klimenko+7 701 742 72 92
04 · USA · Wyoming

Nekker Labs