Kazakhstan Market · TOO Nekker (Almaty)
Commercial HVAC, industrial cooling & 3D/BIM across Kazakhstan. Through TOO Nekker in Almaty (Bostandyk District, Arkhat Microdistrict, Denis Ten Street, 2), we support design institutes, general contractors and developers across Almaty, Astana, Shymkent and industrial regions with verified HVAC packages and 3D/BIM coordination.
Local Office TOO Nekker · Almaty
Standards SN RK / SP RK · ISO 19650
Climate Span -40 °C North to +46 °C South
Almaty Direct +7 701 742 72 92
01 Kazakhstan Market · TOO Nekker (Almaty)
Capabilities for Kazakhstan designers, contractors & owners KZ-01 Air handling & smoke control ventilation Cold-climate heat-recovery AHUs for Astana and seismic-ready MEP assemblies for Almaty.
Central AHUs with rotary, counterflow plate and run-around glycol heat recovery Roof, duct, centrifugal, axial and underground parking jet-fan systems 400 °C / 600 °C smoke extraction fans, pressurisation blowers and fire dampers KZ-02 Chillers, free-cooling plants, fan coils & dry coolers Central cooling plants tailored for data centers, malls, hotels, hospitals and factories.
Integrated free-cooling chillers maximizing winter energy savings in Astana and Karaganda High-ambient chillers and anti-corrosion coated coils for Shymkent, Atyrau and Aktau Quiet EC/AC fan coil units, dry coolers, plate heat exchangers and hydronic pump skids KZ-03 VRF systems, rooftops & hydronic/BMS controls Coordinated climate and building automation packages.
Low-ambient VRF / VRV systems and EVI air-to-water heat pumps Gas-heated and hydronic packaged rooftops for logistics hubs and retail complexes Freeze-protected AHU control panels, balancing/PICV valves and Modbus / BACnet integration KZ-04 3D / BIM MEP coordination & Scan-to-BIM in Almaty and Astana Clash-free Revit / IFC delivery aligned with Kazakhstan BIM requirements and ISO 19650.
48-72 hour federated clash audits and LOD 350-400 installation drawings 2D-to-BIM conversion with model-derived bills of quantities (BOQ) On-site LiDAR laser scanning and LOD 500 As-Built digital twins 02 Project support
Regional engineering considerations across Kazakhstan Region Engineering challenge Nekker Labs approach Benefit Astana, Karaganda, Pavlodar, Ust-Kamenogorsk (-35...-40 °C) Heat wheel frost buildup and hydronic coil freeze risk Pre-heat sizing, glycol loops and cascaded freeze-stat panel logic Uninterrupted winter operation Almaty & foothills (altitude & seismic zone) Reduced air density at elevation and seismic hanger clearances Altitude density fan curve correction and 3D support coordination Verified airflow and smooth inspection sign-off Shymkent, Turkestan, Atyrau, Aktau (+45...+48 °C & coastal air) Summer capacity derating and marine/industrial coil corrosion High-ambient condensers and coated heat-exchanger fins Sustained capacity and coil longevity
03 UZ · KZ
Cities served across Kazakhstan Coordinating equipment supply and BIM engineering across every region of Kazakhstan:
Almaty & Almaty Region Astana Shymkent & Turkestan Atyrau Aktau Karaganda Aktobe Kostanay Pavlodar Ust-Kamenogorsk Taraz
Equipment categories & engineering services UZ HVAC supply, chillers & 3D/BIM in Uzbekistan UZ-01 Tashkent & Tashkent Region (OOO Nekker Labs) KZ-01 Almaty & Foothill Hub (TOO Nekker) KZ-02 Astana & Northern Kazakhstan (-40 C Winter) UZ-02 Samarkand, Bukhara, Navoi & Fergana KZ-03 Shymkent, Atyrau & Aktau (Ex & Marine) 01 Ventilation, AHUs & smoke control (AVZ) 02 High-ambient +50 °C chillers, fan coils & cooling (RØNIQ) 03 Multi-zone VRF/VRV, rooftops & heat pumps 04 HVAC control panels, PICV valves & BMS hydronics 05 Duty-point selection & HVAC schedule audit 06 Smoke Control 400/600 C, Pressurization & Jet Fans 07 Hygienic Medical AHUs, Cleanrooms & HEPA Filtration 08 LiDAR Scan-to-BIM & As-Built LOD 500 + COBie 09 AVZ - Industrial Fans, Smoke Exhaust & Fire Dampers 10 RØNIQ Systems - +50 C Chillers, Fan Coils & Rooftops 11 Industrial Plant Ventilation & Data Center Cooling G-01 Chiller-Fan Coil vs VRF for Hotels, Offices & Malls G-02 Specifying +46...+50 C High-Ambient Chillers G-03 High-Elevation (700-1,000 m) Fan & AHU Correction G-04 Arctic AHUs & Glycol Loops for -40 C Winters G-05 Smoke Control (400/600 C) & EI Damper Checklist G-06 When 3D/BIM (LOD 400) & Scan-to-BIM Pay Off BIM 3D / BIM (LOD 300 - 500) 04 FAQ
Questions on Kazakhstan operations How do we contact the Nekker team in Almaty? TOO Nekker is located in Almaty (Bostandyk District, Arkhat Microdistrict, Denis Ten Street, 2). Contact Alexandr Klimenko at +7 701 742 72 92 or send schedules and drawings to info@nekkerlabs.com.
Do you prepare full technical comparison tables for author supervision sign-off in Kazakhstan? Yes. Every alternative proposal includes a line-by-line comparison of duty points, static pressure, acoustic power, electrical draw, dimensions and weight.
Technical sections & tools Closer to
manufacturer data. Open the public Designer Workspace, browse engineering category guides or sign in to the project platform.