Category 01 · Industrial & Commercial Ventilation
Air handling units, industrial fans & smoke control systems. We select ventilation equipment on verified aerodynamic curves accounting for static vs total pressure, air density, sound levels and electrical supply, backed by our official partnership with Almaty Fan Plant (AVZ) and vetted manufacturers.
Partnership Official AVZ Partner
Selection Verified Duty Point (Q & Esp)
Special Ratings Smoke · Hygienic · Ex
Markets Uzbekistan & Kazakhstan
01 Category 01 · Industrial & Commercial Ventilation
Ventilation product families & duct components VENT-01 Modular Air Handling Units (AHU) Custom-configured supply and extract air treatment units for commercial and cleanroom facilities.
Rotary wheel, plate heat exchanger and glycol run-around heat recovery sections Chilled/hot water, electric, steam and direct-expansion (DX) coils Hygienic medical execution for operating theatres, labs and pharma plants (HEPA H13-H14) VENT-02 General & industrial fans Complete range of duct, roof, centrifugal and axial fans.
Circular and rectangular inline duct fans, high-efficiency EC plug fans Centrifugal and axial roof fans with curb bases and backdraft dampers Explosion-proof (Ex) and corrosion-resistant fans for industrial plants VENT-03 Smoke extraction & stairwell pressurisation Certified life-safety ventilation for underground parkings, atriums and escape cores.
400 °C / 600 °C (120 min) roof, axial and centrifugal smoke extraction fans Stairwell, elevator shaft and lobby pressurisation fan packages Impulse / jet fans for underground car parks VENT-04 Fire dampers, attenuators & air diffusion Complete airside accessories consolidated into one verified equipment package.
Motorized normally-open fire dampers and smoke control dampers Acoustic silencers, flexible connectors, bag/panel filters and insulated dampers Weather louvres, linear slot diffusers and swirl diffusers 02 Project support
Pre-approval ventilation engineering checks Schedule parameter Common procurement pitfall Nekker Labs check Site protection External Static (Esp) vs Total Pressure Selecting fans on total pressure curve leaves ductwork starved of airflow Explicit separation of static and dynamic pressure on published curves Design airflow achieved at terminals Motor nameplate kW vs shaft power Misaligned electrical feeder sizing with MEP electrical schedule Reporting both absorbed power at duty point and motor rated current Zero electrical panel rework Altitude & air temperature Ignoring air density drop in Almaty or hot industrial exhausts Density correction applied before curve intersection True pressure delivery on site
03 UZ · KZ
Ventilation delivery across Uzbekistan & Kazakhstan Supplying commercial, medical, residential and industrial sites:
Tashkent Almaty Astana Shymkent Samarkand Bukhara Atyrau Karaganda
Equipment categories & engineering services UZ HVAC supply, chillers & 3D/BIM in Uzbekistan KZ HVAC supply, ventilation & 3D/BIM in Kazakhstan UZ-01 Tashkent & Tashkent Region (OOO Nekker Labs) KZ-01 Almaty & Foothill Hub (TOO Nekker) KZ-02 Astana & Northern Kazakhstan (-40 C Winter) UZ-02 Samarkand, Bukhara, Navoi & Fergana KZ-03 Shymkent, Atyrau & Aktau (Ex & Marine) 02 High-ambient +50 °C chillers, fan coils & cooling (RØNIQ) 03 Multi-zone VRF/VRV, rooftops & heat pumps 04 HVAC control panels, PICV valves & BMS hydronics 05 Duty-point selection & HVAC schedule audit 06 Smoke Control 400/600 C, Pressurization & Jet Fans 07 Hygienic Medical AHUs, Cleanrooms & HEPA Filtration 08 LiDAR Scan-to-BIM & As-Built LOD 500 + COBie 09 AVZ - Industrial Fans, Smoke Exhaust & Fire Dampers 10 RØNIQ Systems - +50 C Chillers, Fan Coils & Rooftops 11 Industrial Plant Ventilation & Data Center Cooling G-01 Chiller-Fan Coil vs VRF for Hotels, Offices & Malls G-02 Specifying +46...+50 C High-Ambient Chillers G-03 High-Elevation (700-1,000 m) Fan & AHU Correction G-04 Arctic AHUs & Glycol Loops for -40 C Winters G-05 Smoke Control (400/600 C) & EI Damper Checklist G-06 When 3D/BIM (LOD 400) & Scan-to-BIM Pay Off BIM 3D / BIM (LOD 300 - 500) 04 FAQ
Questions on industrial ventilation & AVZ supply What inputs are required for an accurate fan or AHU selection? Provide airflow (m3/h), external static pressure (Pa), mounting configuration, power supply (230 V / 400 V) and air temperature; for AHUs include heating/cooling coil conditions, heat recovery type and filter classes.
Can engineers inspect 3D fan geometry online? Yes, our public interactive 3D stand and assembly workshop (/bim-example.html) displays catalogue fan geometry derived from factory IFC solids.
Technical sections & tools Closer to
manufacturer data. Open the public Designer Workspace, browse engineering category guides or sign in to the project platform.