Uzbekistan Market · OOO Nekker Labs (Tashkent)
HVAC equipment supply, cooling plants & 3D/BIM across Uzbekistan. Operating through OOO Nekker Labs in Tashkent (Yunusabad District, Bogishamol Street, 260A), we deliver duty-point equipment selection, factory-direct ventilation and cooling packages, and 3D/BIM MEP coordination for commercial, hospitality, medical and industrial projects nationwide.
Local Entity OOO Nekker Labs · Tashkent
Codes SHNK / KMK · ISO 19650
Design Climate Summer +46...+50 °C
Commercial Terms UZS DDP w/ VAT or FCA
01 Uzbekistan Market · OOO Nekker Labs (Tashkent)
Core solutions for greenfield & retrofit projects in Uzbekistan UZ-01 Ventilation & smoke control (official AVZ partnership) Direct supply of Almaty Fan Plant (AVZ) air handling units, industrial fans and fire dampers.
Modular supply and extract AHUs for office towers, hotels, hospitals and shopping malls Roof, centrifugal, duct and axial fans for general and industrial ventilation Certified 400 °C / 600 °C smoke extraction fans, pressurisation systems and EI fire dampers UZ-02 High-ambient chillers & fan coils for Tashkent and southern regions Chilled-water plants verified against peak Central Asian summer temperatures.
Air-cooled and water-cooled chillers (including RØNIQ Systems) derated at +46...+50 °C Cassette, ducted (low/medium/high static), wall and floor-ceiling EC/AC fan coil units Hydronic pump skids, dry coolers, buffer tanks, balancing valves and N+1 plant redundancy UZ-03 VRF systems, packaged rooftops & HVAC control panels Single-source engineering coordination across primary plant, terminals and controls.
2-pipe and 3-pipe heat-recovery VRF / VRV systems with verified piping lengths Packaged rooftops and precision CRAC units for retail halls and server rooms Custom HVAC control panels, VFDs, motorized valves and Modbus / BACnet gateways UZ-04 3D / BIM MEP coordination & LiDAR Scan-to-BIM in Tashkent Eliminating ceiling clashes before installation and capturing concealed utilities.
48-72 hour plantroom and riser clash audits from DWG, PDF or RVT/IFC 2D-to-BIM modeling in Revit / OpenBIM IFC (LOD 300-400) with accurate BOQ extraction On-site LiDAR and 360 capture across Tashkent and regional sites for As-Built LOD 500 twins 02 Project support
Engineering factors we verify for projects in Uzbekistan Local condition Risk without verification Nekker Labs engineering check Project outcome +46...+50 °C summer peak in Tashkent, Bukhara, Termez, Navoi Chillers sized at nominal +35 °C trip on high head pressure Selection strictly from factory high-ambient derating tables Full design cooling capacity in July peak High airborne dust & grid voltage swings Rapid coil fouling and nuisance VFD trips Multi-stage filtration, coil maintenance access and panel surge protection Reliable equipment lifecycle 2D discrepancies across Arch, Struct, HVAC & Plumbing Ducts hit beams and lower guestroom/lobby ceiling heights Pre-construction 3D coordination in Revit & Navisworks Zero-rework site installation
03 UZ · KZ
Cities served across Uzbekistan Supporting public, hospitality, healthcare, commercial and industrial developments nationwide:
Tashkent & Tashkent Region Samarkand Bukhara Navoi Fergana Namangan Andijan Karshi Termez Urgench Nukus Jizzakh
Equipment categories & engineering services KZ HVAC supply, ventilation & 3D/BIM in Kazakhstan UZ-01 Tashkent & Tashkent Region (OOO Nekker Labs) KZ-01 Almaty & Foothill Hub (TOO Nekker) KZ-02 Astana & Northern Kazakhstan (-40 C Winter) UZ-02 Samarkand, Bukhara, Navoi & Fergana KZ-03 Shymkent, Atyrau & Aktau (Ex & Marine) 01 Ventilation, AHUs & smoke control (AVZ) 02 High-ambient +50 °C chillers, fan coils & cooling (RØNIQ) 03 Multi-zone VRF/VRV, rooftops & heat pumps 04 HVAC control panels, PICV valves & BMS hydronics 05 Duty-point selection & HVAC schedule audit 06 Smoke Control 400/600 C, Pressurization & Jet Fans 07 Hygienic Medical AHUs, Cleanrooms & HEPA Filtration 08 LiDAR Scan-to-BIM & As-Built LOD 500 + COBie 09 AVZ - Industrial Fans, Smoke Exhaust & Fire Dampers 10 RØNIQ Systems - +50 C Chillers, Fan Coils & Rooftops 11 Industrial Plant Ventilation & Data Center Cooling G-01 Chiller-Fan Coil vs VRF for Hotels, Offices & Malls G-02 Specifying +46...+50 C High-Ambient Chillers G-03 High-Elevation (700-1,000 m) Fan & AHU Correction G-04 Arctic AHUs & Glycol Loops for -40 C Winters G-05 Smoke Control (400/600 C) & EI Damper Checklist G-06 When 3D/BIM (LOD 400) & Scan-to-BIM Pay Off BIM 3D / BIM (LOD 300 - 500) 04 FAQ
Questions on Uzbekistan HVAC supply & projects Can OOO Nekker Labs quote in Uzbekistani Soum (UZS) delivered with customs and VAT? Yes. We provide both factory-direct EXW/FCA quotations for direct import contracts and turnkey local UZS proposals inclusive of freight, customs clearance and VAT.
Do you support Tashkent design institutes during schematic and detailed design? Yes. We assist MEP engineers free of charge with duty-point selection, fan curves, dimensional drawings, acoustic data and schedule reviews under SHNK / KMK codes.
Technical sections & tools Closer to
manufacturer data. Open the public Designer Workspace, browse engineering category guides or sign in to the project platform.