Category 02 · Industrial & Commercial Cooling Plants
Chillers, fan coils & hydronic plants verified for peak summer heat. We engineer and supply chilled-water plants and terminal units for hotels, office towers, shopping malls, hospitals, data centers and factories across Uzbekistan and Kazakhstan, checking every selection at actual ambient and water loop temperatures.
High Ambient Verified at +46...+50 °C
Resilience N+1 Redundant Plants
Product Lines RØNIQ Systems & Vetted Plants
Terminals EC / AC 2-Pipe & 4-Pipe FCUs
01 Category 02 · Industrial & Commercial Cooling Plants
Chilled-water & process cooling equipment scope COOL-01 Air-cooled & water-cooled chillers From modular scroll arrays to heavy-duty screw and oil-free centrifugal chillers.
Modular scroll chillers and reversible heat pumps with built-in N+1 staging High-ambient air-cooled screw chillers rated up to +48...+52 °C and free-cooling units Water-cooled screw and centrifugal chillers paired with cooling towers or dry coolers COOL-02 Fan coil units across all configurations Selected on sensible and total cooling capacity, external static pressure and NC acoustics.
4-way and compact cassette fan coils for offices, lobbies and retail spaces Low, medium and high-static ducted fan coils (AC and quiet EC motors) for hospitality Wall-mounted and floor-ceiling units, 2-pipe and 4-pipe coils, factory-fitted valve kits COOL-03 Dry coolers, cooling towers, condensing units & CRAC Heat rejection for industrial processes, DX AHU coils and mission-critical IT rooms.
Adiabatic and dry coolers, open and closed-circuit evaporative cooling towers Direct-expansion condensing units matched to AHU cooling coils Perimeter and in-row precision air conditioners with humidity control for server rooms COOL-04 Hydronic pump skids & plantroom accessories Complete mechanical room hydronics engineered alongside the chiller.
Duty/standby VFD pump skids, buffer tanks, air/dirt separators and glycol pressurisation units Gasketed and brazed plate heat exchangers isolating glycol roof loops from indoor chilled water Isolating, balancing and motorized control valves for risers and terminal units 02 Project support
Cooling specification checks performed before quotation Check item Typical quoting error Nekker Labs verification Operational result Chiller capacity at peak summer ambient Quoting nominal +35 °C kW loses 18-25% capacity at +46 °C Derated capacity check at city design ambient (+46...+50 °C) Guaranteed indoor comfort in peak summer Fan coil sensible vs total kW Selecting on high-speed total capacity at +27 °C room air Sensible & total verification at design room temperature, 7/12 °C water and medium speed Quiet hotel rooms without humidity issues Ducted FCU external static pressure Supplying 12 Pa low-static units onto 30-50 Pa slot-diffuser ductwork Matching external static pressure to actual plenum and grille resistance Balanced airflow delivery
03 UZ · KZ
Cooling plant delivery across Uzbekistan & Kazakhstan Serving hospitality, healthcare, commercial and industrial projects:
Tashkent Samarkand Bukhara Almaty Astana Shymkent Atyrau Aktau
Equipment categories & engineering services UZ HVAC supply, chillers & 3D/BIM in Uzbekistan KZ HVAC supply, ventilation & 3D/BIM in Kazakhstan UZ-01 Tashkent & Tashkent Region (OOO Nekker Labs) KZ-01 Almaty & Foothill Hub (TOO Nekker) KZ-02 Astana & Northern Kazakhstan (-40 C Winter) UZ-02 Samarkand, Bukhara, Navoi & Fergana KZ-03 Shymkent, Atyrau & Aktau (Ex & Marine) 01 Ventilation, AHUs & smoke control (AVZ) 03 Multi-zone VRF/VRV, rooftops & heat pumps 04 HVAC control panels, PICV valves & BMS hydronics 05 Duty-point selection & HVAC schedule audit 06 Smoke Control 400/600 C, Pressurization & Jet Fans 07 Hygienic Medical AHUs, Cleanrooms & HEPA Filtration 08 LiDAR Scan-to-BIM & As-Built LOD 500 + COBie 09 AVZ - Industrial Fans, Smoke Exhaust & Fire Dampers 10 RØNIQ Systems - +50 C Chillers, Fan Coils & Rooftops 11 Industrial Plant Ventilation & Data Center Cooling G-01 Chiller-Fan Coil vs VRF for Hotels, Offices & Malls G-02 Specifying +46...+50 C High-Ambient Chillers G-03 High-Elevation (700-1,000 m) Fan & AHU Correction G-04 Arctic AHUs & Glycol Loops for -40 C Winters G-05 Smoke Control (400/600 C) & EI Damper Checklist G-06 When 3D/BIM (LOD 400) & Scan-to-BIM Pay Off BIM 3D / BIM (LOD 300 - 500) 04 FAQ
Questions on chillers, fan coils & cooling plants Are hydronic valve kits and thermostats itemized clearly in quotations? Yes. Two-way/three-way motorized valves, balancing valves, flexible hoses and wall/Modbus thermostats are listed as transparent line items.
Can your BIM team verify chiller plantroom clearances before ordering? Yes. Within 48-72 hours we can assemble a 3D Revit/IFC model of your roof or plantroom to verify tube-pull / coil access, pipe slopes and structural supports.
Technical sections & tools Closer to
manufacturer data. Open the public Designer Workspace, browse engineering category guides or sign in to the project platform.