Skip to content
Nekker Labs
Engineering solutions · HVAC, Cooling & 3D/BIM
City Engineering Hub · Tashkent (UZ)

HVAC Equipment Supply, High-Ambient Cooling & 3D/BIM in Tashkent.

Our Tashkent entity OOO Nekker Labs (Yunusabad District, Bogishamol Street, 260A) delivers duty-point HVAC engineering, complete ventilation packages (including AVZ), +50 C RØNIQ Systems chiller plants, fan coils, VRF, controls and 3D/BIM coordination across Tashkent and Tashkent Region.

Local OfficeTashkent · Yunusabad, Bogishamol 260A
Uzbek EntityOOO Nekker Labs (Tax ID 313224797)
Design AmbientSummer +46...+50 C · SHNK / KMK UZ
Field 3D/BIMRevit · Navisworks · LiDAR in Tashkent

Core Capabilities for Tashkent Developers & General Contractors

TAS-01

High-Rise Residential, Towers & New Tashkent Developments

Clash-free shaft, plantroom and podium coordination paired with direct factory HVAC supply.

  • Central Air Handling Units (AHUs), roof and duct fans, and underground parking jet ventilation
  • Fire-rated smoke extraction fans (400/600 C), stairwell/elevator pressurization and EI fire dampers
  • 2D-to-BIM conversion of HVAC, plumbing and electrical drawings into federated Revit / IFC models prior to site installation
TAS-02

Chillers, Fan Coils & VRF Rated for +46...+50 C Summer Peaks

Preventing high-pressure trips and cooling shortfalls during Tashkent peak summer heat.

  • RØNIQ Systems chillers verified against factory derating tables at +46...+50 C ambient and 7/12 C chilled water
  • Low-noise EC ducted and cassette fan coils complete with PICV valve assemblies and pump skids
  • Piping length and elevation correction checks for multi-zone VRF / VRV systems
TAS-03

Hospitals, Pharma Parks & Tashkent Industrial Belt

Process ventilation and precision cooling for Sergeli, Chirchik, Angren and Almalyk facilities.

  • Hygienic medical AHUs with F7-F9-HEPA H14 filtration stages for operating rooms and clean labs
  • AVZ centrifugal, dust-handling, corrosion-resistant and explosion-proof (Ex) industrial fans
  • Dry coolers, cooling towers, hydronic skids and Modbus/BACnet control panels
TAS-04

On-Site LiDAR Scan-to-BIM & 48-72h Clash Audits

Rapid mobilization of laser scanning and BIM coordination engineers to Tashkent construction sites.

  • Express 3D clash audit of critical plantrooms, risers or parking levels within 48-72 hours
  • 2-5 mm terrestrial LiDAR capture of poured concrete structures prior to ductwork fabrication
  • Pre-drywall 360 capture of concealed MEP routing and As-Built LOD 500 + COBie handover models

Engineering Verification for Tashkent Construction Conditions

Tashkent Site FactorUnverified Quote RiskNekker Labs EngineeringProject Outcome
+46...+50 C peak ambient & roof solar loadChillers selected at nominal +35 C trip on high head pressure in JulyTropical condenser sizing and compressor current verification at +48...+50 CUninterrupted +22 C indoor comfort all summer
High airborne dust in dry seasonRapid filter loading drops AHU airflow by 25-35%Fan static pressure sized for dirty-filter final pressure drop + DP sensorsDesign ventilation rate maintained between services
8-9 Richter seismic zone (SHNK)Rigid pipe/duct penetrations suffer vibration and seismic stressFlexible connectors, spring isolators and 3D clearance verificationCode-compliant acoustic and seismic resilience
Fast-track developer schedulesFragmented procurement across 4-5 separate component vendorsSingle-source delivery (equipment + hydronics + controls) managed in TashkentPredictable commissioning without missing parts

Tashkent & Tashkent Region Coverage

Supporting construction sites and design institutes across the capital region:

Tashkent (Yunusabad, Mirabad, Shaykhantakhur, Yashnabad, Sergeli)New TashkentChirchikAngrenAlmalykYangiyulBekabadGazalkent

Tashkent Office Frequently Asked Questions

Where is the Nekker Labs office in Tashkent located?

OOO Nekker Labs is located in Tashkent, Yunusabad District, Bogishamol Street, 260A. Send HVAC schedules (PDF, XLSX, DWG) or Revit/IFC models to info@nekkerlabs.com to arrange an engineering review.

Is Nekker Labs an official AVZ distributor in Tashkent?

Yes. Nekker Labs is the official partner-distributor of Almaty Fan Plant (AVZ) in Uzbekistan, supplying AHUs, industrial and smoke extraction fans, and fire dampers with factory duty-point calculations.

Technical sections & tools

Closer to manufacturer data.

Open the public Designer Workspace, browse engineering category guides or sign in to the project platform.

Let’s start with your project.

Email your HVAC equipment schedule, 3D/BIM pilot drawings or supply enquiry for engineering review.

Write an email
Projects and partnershipsinfo@nekkerlabs.com
Contacts
Rinat BaitemirProjects & Partnerships
+90 501 552 29 11
Alexandr KlimenkoKazakhstan · Almaty
+7 701 742 72 92
DIRECT PROJECT SUBMISSION

Attach drawings, equipment schedules, or BIM models

Upload PDF, DWG, RVT, IFC, Excel, or ZIP packages (up to 5 files, 100 MB total). Your submission creates an instant CRM dossier and alerts the regional desk.

Required scope
Project files or schedules (optional)
Drag and drop files here or click to browsePDF, XLSX, DWG, DXF, RVT, IFC, ZIP, PNG/JPG - up to 5 files, max 50 MB each / 100 MB batch
Offices & addresses
01 · Uzbekistan · Tashkent

OOO Nekker Labs

Uzbekistan, Tashkent, Yunusabad District, Bogishamol Street, 260A

Rinat Baitemirinfo@nekkerlabs.com
02 · Kazakhstan · Almaty

TOO Nekker

Kazakhstan, Almaty, Bostandyk District, Arkhat Microdistrict, Denis Ten Street, 2

Alexandr Klimenko+7 701 742 72 92
04 · USA · Wyoming

Nekker Labs

1309 Coffeen Avenue, STE 1200, Sheridan, Wyoming 82801