Engineering Guide 04 · Arctic HVAC Design
Ventilation & Cooling at -40 C: Frost-Protected AHUs & Glycol Loops. Practical rules for preventing burst hydronic coils, frozen plate heat exchangers and winter chiller trips across Astana, Karaganda and Pavlodar.
Winter Design -35...-40 C (SN RK)
Heat Recovery Rotary / Glycol / Bypass Plate
Glycol Loop 40 - 50% Propylene Glycol
Controls Dual Air/Water Freeze Protection
01 Engineering Guide 04 · Arctic HVAC Design
Core Rules for Trouble-Free Northern Kazakhstan Winters WIN-01 50 mm Thermal-Break Casings & Heated Dampers Standard 25 mm casings sweat and ice up inside plantrooms at -35 C.
Specify 50-60 mm mineral-wool thermal-break panels and insulated spring-return intake dampers Use snow-trap intake louvers to stop steppe blowing snow from clogging pre-filters WIN-02 Glycol Recalculation & Free Cooling ROI 45% propylene glycol protects outdoor loops but demands higher flow and pump head.
Check exact flow penalty in our online calculator (/en/calculators/#calc-hydronics) Astana ambient air enables compressor-free Free Cooling for data centers over 6 months per year 02 Project support
Hydronic Coil Freeze-Protection Checklist Protection Element Safeguard Action Common Cost-Cutting Error Nekker Labs Standard Capillary air freeze-stat Stops fan & closes intake damper below +5 C Single point sensor in one corner Full-face serpentine capillary across coil Return-water immersion sensor Drives 3-way valve to 100% in standby Uninsulated strap-on sensor Immersion well in coil return header
03 UZ · KZ
Northern Kazakhstan Coverage Supplied and contracted via TOO Nekker:
Astana Karaganda Pavlodar Kostanay Petropavlovsk Ust-Kamenogorsk
Equipment categories & engineering services UZ HVAC supply, chillers & 3D/BIM in Uzbekistan KZ HVAC supply, ventilation & 3D/BIM in Kazakhstan UZ-01 Tashkent & Tashkent Region (OOO Nekker Labs) KZ-01 Almaty & Foothill Hub (TOO Nekker) KZ-02 Astana & Northern Kazakhstan (-40 C Winter) UZ-02 Samarkand, Bukhara, Navoi & Fergana KZ-03 Shymkent, Atyrau & Aktau (Ex & Marine) 01 Ventilation, AHUs & smoke control (AVZ) 02 High-ambient +50 °C chillers, fan coils & cooling (RØNIQ) 03 Multi-zone VRF/VRV, rooftops & heat pumps 04 HVAC control panels, PICV valves & BMS hydronics 05 Duty-point selection & HVAC schedule audit 06 Smoke Control 400/600 C, Pressurization & Jet Fans 07 Hygienic Medical AHUs, Cleanrooms & HEPA Filtration 08 LiDAR Scan-to-BIM & As-Built LOD 500 + COBie 09 AVZ - Industrial Fans, Smoke Exhaust & Fire Dampers 10 RØNIQ Systems - +50 C Chillers, Fan Coils & Rooftops 11 Industrial Plant Ventilation & Data Center Cooling G-01 Chiller-Fan Coil vs VRF for Hotels, Offices & Malls G-02 Specifying +46...+50 C High-Ambient Chillers G-03 High-Elevation (700-1,000 m) Fan & AHU Correction G-05 Smoke Control (400/600 C) & EI Damper Checklist G-06 When 3D/BIM (LOD 400) & Scan-to-BIM Pay Off BIM 3D / BIM (LOD 300 - 500) 04 FAQ
Arctic HVAC Questions Does TOO Nekker supply matched AHU + mixing skid + freeze-protection control panels? Yes. We deliver factory-matched mechanical, hydronic and control packages verified for -40 C operation.
Technical sections & tools Closer to
manufacturer data. Open the public Designer Workspace, browse engineering category guides or sign in to the project platform.